PRODUCT REFERENCE

CT X-ray Tube Reference — All Models

A single reference for every RIMION CT tube, X-ray tube and tube insert — full specifications, compatible GE, Siemens, Philips and Canon scanners, and model-by-model comparison. Compatible with Neusoft, Minfound, United Imaging, Sino Vision, Anke, Quantum and other CT brands.

Master Comparison Table

All RIMION CT tubes, X-ray tubes and tube inserts at a glance — heat capacity, voltage, focal spots, target material and compatible brands.

Model Type Heat Capacity Voltage Focal Spot (mm) Target Material Brands
MH3501CT3.5 MHU140 kV0.9×0.5 / 1.2×1.2Rhenium tungsten molybdenum graphiteGE
MH3502CT3.5 MHU140 kV0.8×0.4 / 0.8×0.7Rhenium tungsten molybdenum graphiteSiemens
MH3504ACT————Canon
MH3505CT3.5 MHU140 kV0.7×0.8 / 1.2×1.4Rhenium tungsten molybdenum graphiteNeusoft, Minfound, UI, Sino Vision, Anke, Quantum, Campo
MH4006CT4.0 MHU140 kV0.4×0.7 / 0.6×1.3Rhenium tungsten molybdenum graphitePhilips, Neusoft
MH5006CT5.3 MHU140 kV0.5×1.0 / 1.0×1.0Rhenium tungsten molybdenum graphitePhilips, UI, Neusoft, Anke, Minfound, Sino Vision, Quantum, Shinva, Envision
MH6002CT6.3 MHU140 kV0.9×0.7 / 1.2×1.1Tungsten rhenium alloySiemens
MH6002ACT6.0 MHU140 kV0.8×0.7 / 0.8×0.5—Siemens
MH6003LCT8.0 MHU140 kV0.5×1.0 / 1.0×1.0Rhenium, TungstenPhilips
MH6301CT6.3 MHU140 kV0.9×0.7 / 1.2×1.1Tungsten rhenium alloyGE
MH0304X-ray—150 kV—Rhenium tungsten molybdenum graphiteGeneral X-ray
MH0822X-ray—150 kV—Tungsten-rhenium alloyGeneral X-ray
MH1505X-ray—150 kV—Rhenium tungsten molybdenum graphiteGeneral X-ray
MX0304Insert—150 kV—Rhenium tungsten molybdenum graphiteReplaceable insert
MX0822Insert—150 kV—Tungsten-rhenium alloyReplaceable insert
MX1505Insert—150 kV—Rhenium tungsten molybdenum graphiteReplaceable insert

Medical CT Tubes — Full Specifications

Ten CT tube models covering GE, Siemens, Philips, Canon and major Chinese CT brands.

CTMH3501 — GE-Compatible CT Tube

1:1 drop-in replacement for the GE MX165. High-load-bearing metal bearings and high-vacuum sealing for stable imaging on GE scanners.

Specifications

X-ray tube component focus0.9×0.5 mm / 1.2×1.2 mm
Nominal X-ray tube voltage140 kV
Nominal CT anode input power28 kW
Nominal continuous input power3.7 kW
Target surface materialRhenium tungsten molybdenum based graphite target
Target angle7°
Product weightAbout 70 kg
Built-in core heat capacity3.5 MHU (2.8 MJ)

Compatible CT systems

  • GE HiSpeed
  • GE BrightSpeed Elite / Edge / Excel Select
  • GE Optima CT520
  • GE Optima Advance
  • GE Revolution Advance
  • GE Revolution Eagle

Frequently asked questions

Which GE CT scanners is the MH3501 compatible with?

The MH3501 is compatible with GE HiSpeed, BrightSpeed Elite/Edge/Excel Select, Optima CT520, Optima Advance, Revolution Advance and Revolution Eagle.

Is the MH3501 a drop-in replacement for the GE MX165?

Yes. The MH3501 is engineered as an original factory-level precise adaptation to the GE MX165 — no mechanical modification, no firmware changes, and no scanner reconfiguration required.

CTMH3502 — Siemens-Compatible CT Tube

Direct alternative for Siemens DURA202, DURA352 and CHRONON tubes. Fully automated intelligent welding process for vacuum reliability.

Specifications

X-ray tube component focus0.8×0.4 mm / 0.8×0.7 mm
Nominal X-ray tube voltage140 kV
Nominal CT anode input power28 kW / 34 kW
Nominal continuous input power4.5 kW
Target surface materialRhenium tungsten molybdenum based graphite target
Target angle7°
Maximum anode heat capacity3.5 MHU (2.485 MJ)

Compatible CT systems

  • Siemens Emotion Series
  • Siemens Scope Series
  • Siemens Go now / Go up

Frequently asked questions

Which Siemens tubes does the MH3502 replace?

The MH3502 is a direct alternative for the Siemens DURA202, DURA352 and CHRONON X-ray tubes.

What manufacturing process does the MH3502 use?

A fully automated intelligent welding process for vacuum sealing and structural stability, plus intelligent aging training before shipment to eliminate early-failure risk.

CTMH3504A — Canon-Compatible CT Tube

High-performance alternative CT tube for Canon Alexion and Asteion CT systems.

Compatible CT systems

  • Canon Alexion 16
  • Canon Alexion Access
  • Canon Asteion VF
  • Canon Asteion 4
  • Canon Asteion S4

Frequently asked questions

Which Canon CT scanners is the MH3504A compatible with?

The MH3504A is compatible with Canon Alexion 16, Alexion Access, Asteion VF, Asteion 4 and Asteion S4 CT scanners.

Is the MH3504A a drop-in replacement?

Yes. The MH3504A is engineered as a 1:1 drop-in replacement for the corresponding Canon Alexion and Asteion CT tubes, with no additional equipment structure modification required.

CTMH3505 — Chinese CT Brand Tube

Alternative to the GS307X series tube — 3.5 MHU metal tube, lightweight and compact for Chinese CT systems.

Specifications

X-ray tube component focus0.7×0.8 mm / 1.2×1.4 mm
Nominal X-ray tube voltage140 kV
Nominal CT anode input power29 kW / 48 kW
Nominal continuous input power4.2 kW
Target surface materialRhenium tungsten molybdenum based graphite target
Target angle7°
Product weightAbout 50 kg
Built-in core heat capacity3.5 MHU (2.8 MJ)

Compatible CT systems

  • Neusoft Neuviz ACE / SP
  • Minfound ScintCare 775 / e531 / M631 / CT 16E
  • Minfound Blue 735 / 755 / 765
  • United Imaging uCT 528
  • Sino Vision Insitum CT338 / 358 / 3585
  • Anke ANATOM 32Fit
  • Quantum CT Q560 / 560a / 560M
  • Campo Imaging Precision 128

Frequently asked questions

What original tube does the MH3505 replace?

The MH3505 is an alternative to the GS307X series tube — compatible with multiple 16-row CT models from Neusoft, Minfound, United Imaging, Anke and other Chinese brands.

Is the MH3505 a metal tube?

Yes. The MH3505 is a 3.5 MHU metal tube with a lightweight and compact design that reduces equipment operating load and delivers stable performance under continuous scanning.

CTMH4006 — Philips & Neusoft CT Tube

4.0 MHU glass tube core with efficient heat dissipation for continuous scanning on Philips and Neusoft systems.

Specifications

X-ray tube assembly focal spot0.4×0.7 mm / 0.6×1.3 mm
Nominal X-ray tube voltage140 kV
Nominal CT anode input power28 kW / 48 kW
Nominal continuous input power6 kW
Target surface materialRhenium tungsten molybdenum based graphite target
Target angle7°
Product weightAbout 67 kg
Built-in core heat capacity4.0 MHU (3.0 MJ)

Compatible CT systems

  • Philips Access Dual
  • Philips MX4000
  • Philips Access16
  • Philips MX6000
  • Neusoft Neuviz Twin
  • Neusoft Neuviz Dual
  • Neusoft Neuviz 16 Classic

Frequently asked questions

What makes the MH4006 different from other RIMION CT tubes?

The MH4006 uses a mature glass-metal connection process for stable sealing under high pressure and temperature, and its glass tube core leverages excellent thermal radiation for fast heat dissipation.

Is the MH4006 lighter than comparable tubes?

Yes. Under the same thermal capacity conditions, glass tube core products have a lighter self-weight, reducing the operating burden on CT equipment and lowering mechanical wear.

CTMH5006 — High-Capacity 16-Row CT Tube

5.3 MHU with a 190mm large diameter target disk — alternative to the DU5008 and CTR2150 tubes.

Specifications

X-ray tube component focus0.5×1.0 mm / 1.0×1.0 mm
Nominal X-ray tube voltage140 kV
Nominal CT anode input power36 kW (≥35 kW) / 50 kW (≥48 kW)
Nominal continuous input power6.0 kW
Target surface materialRhenium tungsten molybdenum based graphite target
Target angle7°
Product weightAbout 95 kg
Built-in core heat capacity5.3 MHU (3.8 MJ)

Compatible CT systems

  • Philips MX16 / 16EVO
  • United Imaging uCT510 / 512 / 530 / 550
  • Neusoft Neuviz 16 / 16Essence / 16Platinum
  • Anke ANATOM 16 / 16HD
  • Minfound ScintCare CT16 / CT32 / mCT32 / 736
  • Sino Vision Insitum 16 / 32 / 64S / CT368 / 398 / 568
  • Quantum CT Q580 / 588
  • Shinva XHCT-16
  • Envision LCT16

Frequently asked questions

What original tubes does the MH5006 replace?

The MH5006 is an alternative to the DU5008 and CTR2150 tubes — compatible with multiple 16-row CT models from Philips, Neusoft, United Imaging, Anke and Minfound.

What is the heat capacity of the MH5006?

5.3 MHU (3.8 MJ), with a 190mm large diameter target disk and an oil cooling system for stable heat dissipation under high load.

CTMH6002 — Siemens Somatom CT Tube

6.3 MHU tube for Siemens Somatom CT scanners with tungsten rhenium alloy target.

Specifications

Maximum anode heat content6.3 MHU
Nominal X-ray tube voltage140 kV
Nominal CT anode input power24 kW / 53 kW
Nominal continuous input power3.7 kW
Nominal focal spot value0.9×0.7 / 1.2×1.1
Target materialTungsten rhenium alloy

Compatible CT systems

  • Siemens Somatom Emotion 6
  • Siemens Somatom Emotion 16
  • Siemens Somatom Scope
  • Siemens Somatom Scope Power
  • Siemens Somatom Perspective 64 / 128
  • Siemens Somatom Emotion PET

Frequently asked questions

Which Siemens CT scanners is the MH6002 compatible with?

The MH6002 fits Siemens Somatom Emotion 6, Emotion 16, Scope, Scope Power, Perspective 64/128 and Emotion PET.

What target material does the MH6002 use?

A tungsten rhenium alloy target — delivering high thermal stability across continuous scanning protocols.

CTMH6002A — Siemens Perspective 64 Tube

6.0 MHU CT tube dedicated to the Siemens Somatom Perspective 64 scanner.

Specifications

Anode heat content6.0 MHU
Nominal voltage140 kV
Large focal spot size0.8×0.7
Small focal spot size0.8×0.5
Nominal anode input power28 kW / 55 kW
Nominal continuous input power4.1 kW

Compatible CT systems

  • Siemens SOMATOM Perspective 64

Frequently asked questions

Which scanner is the MH6002A designed for?

The MH6002A is designed specifically for the Siemens SOMATOM Perspective 64 CT scanner.

What is the anode heat content of the MH6002A?

6.0 MHU, with dual focal spots of 0.8×0.7 and 0.8×0.5 for resolution and load flexibility.

CTMH6003L — Philips Brilliance CT Tube

8.0 MHU high-capacity tube for Philips Brilliance and Ingenuity CT scanners.

Specifications

Maximum anode heat capacity8.0 MHU
Nominal X-ray tube voltage140 kV
Nominal CT anode input power60 kW / 80 kW
Nominal continuous input power6.1 kW
Nominal focal spot value0.5×1.0 / 1.0×1.0
Anode target materialRhenium, Tungsten

Compatible CT systems

  • Philips Brilliance CT 6 / 10 / 16
  • Philips Ingenuity Flex 16

Frequently asked questions

Which Philips CT scanners is the MH6003L compatible with?

The MH6003L fits Philips Brilliance CT 6, CT 10, CT 16 and Ingenuity Flex 16 CT scanners.

What is the maximum anode heat capacity of the MH6003L?

8.0 MHU — the highest heat capacity in the RIMION CT tube range, designed for high-throughput clinical environments.

CTMH6301 — GE Optima & Discovery CT Tube

6.3 MHU tube for GE Optima, BrightSpeed, Discovery PET/CT, HiSpeed and LightSpeed systems.

Specifications

Maximum anode heat content6.3 MHU
Nominal X-ray tube voltage140 kV
Nominal CT anode input power24 kW / 53 kW
Nominal continuous input power3.7 kW
Nominal focal spot value0.9×0.7 / 1.2×1.1
Target materialTungsten rhenium alloy

Compatible CT systems

  • GE Optima 540
  • GE CT660
  • GE BrightSpeed Edge / Elite / Excel
  • GE Discovery PET/CT 600 / RX
  • GE HiSpeed CT
  • GE LightSpeed 16

Frequently asked questions

Which GE CT scanners is the MH6301 compatible with?

The MH6301 fits GE Optima 540, CT660, BrightSpeed Edge/Elite/Excel, Discovery PET/CT 600/RX, HiSpeed CT and LightSpeed 16.

What is the heat capacity of the MH6301?

6.3 MHU with a tungsten rhenium alloy target — suited to 64-row and PET/CT protocols.

X-ray Tubes — Full Specifications

Three 150 kV X-ray tube models with natural cooling for medical and veterinary imaging.

X-rayMH0304 — 150 kV X-ray Tube

Rhenium tungsten molybdenum graphite target with natural cooling.

Specifications

Nominal X-ray tube voltage150 kV
Target angle12.0°
Target surface materialRhenium tungsten molybdenum based graphite target
Cooling methodNatural cooling

Frequently asked questions

What are the key specifications of the MH0304?

150 kV nominal voltage, 12.0° target angle, rhenium tungsten molybdenum based graphite target, natural cooling.

What cooling method does the MH0304 use?

Natural cooling — no oil or liquid cooling circuit required.

X-rayMH0822 — 150 kV X-ray Tube

Tungsten-rhenium alloy target with natural cooling.

Specifications

Nominal X-ray tube voltage150 kV
Target angle12.0°
Target surface materialTungsten-rhenium alloy
Cooling methodNatural cooling

Frequently asked questions

What target material does the MH0822 use?

A tungsten-rhenium alloy target surface at a 12.0° target angle.

What cooling method does the MH0822 use?

Natural cooling — for simpler installation and reduced maintenance.

X-rayMH1505 — 150 kV X-ray Tube

Rhenium tungsten molybdenum graphite target with natural cooling.

Specifications

Nominal X-ray tube voltage150 kV
Target angle12.0°
Target surface materialRhenium tungsten molybdenum based graphite target
Cooling methodNatural cooling

Frequently asked questions

What are the key specifications of the MH1505?

150 kV nominal voltage, 12.0° target angle, rhenium tungsten molybdenum based graphite target, natural cooling.

How does the MH1505 differ from the MH0304?

Both use the same target material, angle, voltage and cooling — the MH1505 is a different form factor for a different scanner family.

Tube Inserts — Full Specifications

Three replaceable 150 kV X-ray tube inserts for lower-cost refurbishment of compatible tubes.

InsertMX0304 — Tube Insert

Rhenium tungsten molybdenum graphite target with natural cooling.

Specifications

Nominal X-ray tube voltage150 kV
Target angle12.0°
Target surface materialRhenium tungsten molybdenum based graphite target
Cooling methodNatural cooling

Frequently asked questions

What is a tube insert?

A tube insert is the internal core of an X-ray tube — anode, cathode and target — that goes inside an existing housing. It is used for lower-cost refurbishment of compatible tubes rather than a full tube replacement.

What are the key specs of the MX0304 insert?

150 kV nominal voltage, 12.0° target angle, rhenium tungsten molybdenum based graphite target, natural cooling.

InsertMX0822 — Tube Insert

Tungsten-rhenium alloy target with natural cooling.

Specifications

Nominal X-ray tube voltage150 kV
Target angle12.0°
Target surface materialTungsten-rhenium alloy
Cooling methodNatural cooling

Frequently asked questions

What target material does the MX0822 insert use?

A tungsten-rhenium alloy target surface at a 12.0° target angle.

Is the MX0822 insert a full tube or a core?

It is a tube insert — the internal core only. It is installed into a compatible housing, not a complete tube assembly.

InsertMX1505 — Tube Insert

Rhenium tungsten molybdenum graphite target with natural cooling.

Specifications

Nominal X-ray tube voltage150 kV
Target angle12.0°
Target surface materialRhenium tungsten molybdenum based graphite target
Cooling methodNatural cooling

Frequently asked questions

What are the key specifications of the MX1505 insert?

150 kV nominal voltage, 12.0° target angle, rhenium tungsten molybdenum based graphite target, natural cooling.

How does the MX1505 differ from the MX0304?

Same target material, angle, voltage and cooling — different form factor for a different housing family.

Products by Brand Compatibility

Find the right RIMION tube for your CT scanner brand.

GEGE Healthcare-Compatible Tubes

  • MH3501GE HiSpeed, BrightSpeed Elite/Edge/Excel Select, Optima CT520, Optima Advance, Revolution Advance, Revolution Eagle
  • MH6301GE Optima 540, CT660, BrightSpeed Edge/Elite/Excel, Discovery PET/CT 600/RX, HiSpeed CT, LightSpeed 16

SISiemens-Compatible Tubes

  • MH3502Siemens Emotion, Scope, Go now/up — replaces DURA202, DURA352, CHRONON
  • MH6002Siemens Somatom Emotion 6/16, Scope, Scope Power, Perspective 64/128, Emotion PET
  • MH6002ASiemens Somatom Perspective 64

PHPhilips-Compatible Tubes

  • MH4006Philips Access Dual, MX4000, Access16, MX6000
  • MH5006Philips MX16 / 16EVO — replaces DU5008 / CTR2150
  • MH6003LPhilips Brilliance CT 6/10/16, Ingenuity Flex 16

CACanon-Compatible Tubes

  • MH3504ACanon Alexion 16, Alexion Access, Asteion VF, Asteion 4, Asteion S4

CNChinese CT Brand-Compatible Tubes

  • MH3505Neusoft Neuviz ACE/SP, Minfound ScintCare & Blue, United Imaging uCT 528, Sino Vision Insitum, Anke ANATOM 32Fit, Quantum CT Q560, Campo Precision 128 — replaces GS307X
  • MH4006Neusoft Neuviz Twin, Dual, 16 Classic
  • MH5006United Imaging uCT510/512/530/550, Neusoft Neuviz 16/16Essence/16Platinum, Anke ANATOM 16/16HD, Minfound ScintCare CT16/CT32/mCT32/736, Sino Vision Insitum 16/32/64S/CT368/398/568, Quantum CT Q580/588, Shinva XHCT-16, Envision LCT16

XRGeneral X-ray Tubes & Inserts

  • MH0304150 kV X-ray tube — graphite target, natural cooling
  • MH0822150 kV X-ray tube — tungsten-rhenium alloy, natural cooling
  • MH1505150 kV X-ray tube — graphite target, natural cooling
  • MX0304150 kV tube insert — graphite target
  • MX0822150 kV tube insert — tungsten-rhenium alloy
  • MX1505150 kV tube insert — graphite target

How to Choose a CT Tube

Three things matter most when selecting a replacement CT tube — heat capacity, focal spot, and target material.

Heat Capacity (MHU)

MHU stands for Million Heat Units — the anode's heat storage capacity. Higher MHU means the tube can handle longer continuous scanning without thermal degradation. RIMION CT tubes range from 3.5 MHU (standard diagnostic CT) to 8.0 MHU (high-throughput Brilliance and Ingenuity systems). Always match the original tube's MHU rating — higher is not always better, because scanner protocols are calibrated to the original rating.

Focal Spot Size

Dual-focal CT tubes have a small spot and a large spot. The small spot (e.g. 0.7×0.8 mm) delivers higher spatial resolution for fine diagnostic detail. The large spot (e.g. 1.2×1.4 mm) delivers higher power handling for high-load scanning. The scanner switches between them automatically depending on the clinical protocol — so both spot sizes must match the original tube for correct behavior.

Target Material

RIMION uses two target material families: rhenium tungsten molybdenum based graphite (most CT tubes) and tungsten-rhenium alloy (MH6002, MH6002A, MH6301). Both deliver high thermal stability and long service life. Graphite-backed targets dissipate heat more efficiently for continuous scanning; tungsten-rhenium alloy targets offer higher mechanical strength for high-power protocols.

General Questions

Common questions about RIMION products, compatibility, warranty and export.

How many CT tube models does RIMION manufacture?

RIMION manufactures 12 medical CT tube models, 3 X-ray tube models and 3 replaceable tube inserts — 18 catalog entries in total. Each tube is engineered to OEM-equivalent standards and is supplied factory-direct from Zhuhai, China.

Which RIMION CT tube fits a GE scanner?

The MH3501 fits GE HiSpeed, BrightSpeed Elite/Edge/Excel Select, Optima CT520, Optima Advance, Revolution Advance and Revolution Eagle. The MH6301 fits GE Optima 540, CT660, BrightSpeed Edge/Elite/Excel, Discovery PET/CT 600/RX, HiSpeed CT and LightSpeed 16.

Which RIMION CT tube fits a Siemens scanner?

The MH3502 fits Siemens Emotion, Scope and Go now/up. The MH6002 fits Siemens Somatom Emotion 6/16, Scope, Scope Power, Perspective 64/128 and Emotion PET. The MH6002A fits Siemens Somatom Perspective 64.

Which RIMION CT tube fits a Philips scanner?

The MH4006 fits Philips Access Dual, MX4000, Access16 and MX6000. The MH5006 fits Philips MX16 / 16EVO. The MH6003L fits Philips Brilliance CT 6/10/16 and Ingenuity Flex 16.

What is the difference between a CT tube and a tube insert?

A CT tube is the complete X-ray tube assembly including housing, bearings, cooling and connectors — installed as a unit. A tube insert is the internal core (anode, cathode, target) that goes inside an existing housing, and is used for lower-cost refurbishment of compatible tubes.

What does MHU mean in CT tube specifications?

MHU stands for Million Heat Units — a measure of the anode's heat storage capacity. Higher MHU means the tube can handle longer continuous scanning without thermal degradation. RIMION CT tubes range from 3.5 MHU to 8.0 MHU.

What is the difference between small and large focal spot?

The small focal spot (e.g. 0.7×0.8mm) delivers higher spatial resolution — used for fine diagnostic detail. The large focal spot (e.g. 1.2×1.4mm) delivers higher power handling — used for high-load scanning. Dual-focal tubes switch between them automatically depending on the protocol.

What target material do RIMION CT tubes use?

RIMION CT tubes use either rhenium tungsten molybdenum based graphite target (for most CT tubes) or tungsten-rhenium alloy (for MH6002, MH6002A and MH6301). Both deliver high thermal stability and long service life.

Are RIMION tubes compatible with Chinese CT brands?

Yes. The MH3505 is compatible with Neusoft Neuviz ACE/SP, Minfound ScintCare and Blue series, United Imaging uCT 528, Sino Vision Insitum, Anke ANATOM 32Fit, Quantum CT Q560 and Campo Imaging Precision 128. The MH4006 also fits Neusoft Neuviz Twin, Dual and 16 Classic.

What warranty does RIMION provide?

Every RIMION CT tube, X-ray tube and tube insert comes with a 12-month warranty covering manufacturing defects, plus full-lifecycle after-sales support and 24/7 technical assistance.

How do I choose between different MHU ratings?

Match the MHU to your scanning workload: 3.5 MHU for standard diagnostic CT, 4.0–5.3 MHU for 16-row CT, 6.3 MHU for 64-row CT and PET/CT, and 8.0 MHU for high-throughput and Brilliance/Ingenuity systems. Higher MHU is not always needed — match the original tube rating for correct protocol behavior.

Where is RIMION located and do they export worldwide?

RIMION is based in Zhuhai, Guangdong Province, China. The company exports CT tubes, X-ray tubes and inserts to more than 30 countries across South America, Asia, Eastern Europe, Central Asia, the Middle East and Africa.

Need Help Choosing the Right Tube?

Send us your scanner brand, model number and required quantity — our team will match the correct RIMION tube and reply within 24 hours.