CT X-ray Tube Replacement — Find the Right Tube
A complete replacement guide mapping scanner models from GE, Siemens, Philips, Canon and major Chinese CT brands to the corresponding RIMION replacement tube. Find your scanner below.
GE CT X-ray Tube Replacement
RIMION supplies two drop-in replacement tubes for GE CT scanners — covering the HiSpeed and BrightSpeed families, Optima, Revolution, Discovery PET/CT and LightSpeed systems.
| Replaces GE tube | MX165 |
|---|---|
| RIMION replacement | MH3501 |
| Compatible GE scanners | HiSpeed · BrightSpeed Elite / Edge / Excel Select · Optima CT520 · Optima Advance · Revolution Advance · Revolution Eagle |
| Compatible GE scanners | Optima 540 · CT660 · BrightSpeed Edge / Elite / Excel · Discovery PET/CT 600 / RX · HiSpeed CT · LightSpeed 16 |
|---|---|
| RIMION replacement | MH6301 |
Which RIMION tube replaces the GE MX165?
The RIMION MH3501 is a 1:1 drop-in replacement for the GE MX165 — compatible with GE HiSpeed, BrightSpeed Elite/Edge/Excel Select, Optima CT520, Optima Advance, Revolution Advance and Revolution Eagle.
Which tube is used with GE Optima 540 and Discovery PET/CT?
The RIMION MH6301 fits GE Optima 540, CT660, BrightSpeed, Discovery PET/CT 600/RX, HiSpeed CT and LightSpeed 16 CT scanners.
Siemens CT X-ray Tube Replacement
RIMION provides three replacement tubes for Siemens CT scanners — covering DURA202, DURA352, CHRONON and the Somatom family from Emotion through Perspective 64/128 and PET/CT.
| Replaces Siemens tubes | DURA202 · DURA352 · CHRONON |
|---|---|
| RIMION replacement | MH3502 |
| Compatible Siemens scanners | Emotion Series · Scope Series · Go now / Go up |
| Compatible Siemens scanners | Somatom Emotion 6 · Emotion 16 · Scope · Scope Power · Perspective 64 / 128 · Emotion PET |
|---|---|
| RIMION replacement | MH6002 |
| Compatible Siemens scanners | Somatom Perspective 64 |
|---|---|
| RIMION replacement | MH6002A |
Which RIMION tube replaces Siemens DURA202, DURA352 and CHRONON?
The RIMION MH3502 is a direct alternative for the Siemens DURA202, DURA352 and CHRONON tubes — compatible with Siemens Emotion, Scope and Go now/up systems.
Which tube fits Siemens Somatom Perspective 64?
The RIMION MH6002A is designed specifically for the Siemens Somatom Perspective 64. The MH6002 covers Somatom Emotion 6/16, Scope, Scope Power, Perspective 64/128 and Emotion PET.
Philips CT X-ray Tube Replacement
RIMION supplies three replacement tubes for Philips CT scanners — covering Access, MX4000, MX6000, MX16 / 16EVO, Brilliance CT and Ingenuity Flex 16, including the DU5008 and CTR2150 replacements.
| Compatible Philips scanners | Access Dual · MX4000 · Access16 · MX6000 |
|---|---|
| RIMION replacement | MH4006 |
| Replaces Philips tubes | DU5008 · CTR2150 |
|---|---|
| RIMION replacement | MH5006 |
| Compatible Philips scanners | MX16 · 16EVO |
| Compatible Philips scanners | Brilliance CT 6 / 10 / 16 · Ingenuity Flex 16 |
|---|---|
| RIMION replacement | MH6003L |
Which RIMION tube replaces the Philips CTR2150?
The RIMION MH5006 is an alternative to the Philips DU5008 and CTR2150 tubes — compatible with Philips MX16 / 16EVO and multiple 16-row CT models from other brands.
Which tube fits Philips Brilliance CT 6/10/16 and Ingenuity Flex 16?
The RIMION MH6003L fits Philips Brilliance CT 6, CT 10, CT 16 and Ingenuity Flex 16 — with an 8.0 MHU heat capacity suited to high-throughput clinical environments.
Canon CT X-ray Tube Replacement
RIMION supplies one replacement tube for Canon Alexion and Asteion CT systems — a 1:1 drop-in alternative for the corresponding Canon tube.
| Compatible Canon scanners | Alexion 16 · Alexion Access · Asteion VF · Asteion 4 · Asteion S4 |
|---|---|
| RIMION replacement | MH3504A |
Which RIMION tube is compatible with Canon Alexion and Asteion?
The RIMION MH3504A is compatible with Canon Alexion 16, Alexion Access, Asteion VF, Asteion 4 and Asteion S4 CT scanners.
Is the MH3504A a direct drop-in replacement?
Yes. The MH3504A is engineered as a 1:1 drop-in replacement for the corresponding Canon Alexion and Asteion CT tubes — no additional equipment structure modification required.
Chinese CT X-ray Tube Replacement
RIMION supplies three replacement tubes covering the major Chinese CT brands — Neusoft, Minfound, United Imaging, Sino Vision, Anke, Quantum, Shinva, Envision and Campo Imaging.
| Replaces original tube | GS307X series |
|---|---|
| RIMION replacement | MH3505 |
| Compatible scanners | Neusoft Neuviz ACE / SP · Minfound ScintCare 775 / e531 / M631 / CT 16E · Minfound Blue 735 / 755 / 765 · United Imaging uCT 528 · Sino Vision Insitum CT338 / 358 / 3585 · Anke ANATOM 32Fit · Quantum CT Q560 / 560a / 560M · Campo Precision 128 |
| Compatible scanners | Neusoft Neuviz Twin · Neuviz Dual · Neuviz 16 Classic |
|---|---|
| RIMION replacement | MH4006 |
| Compatible scanners | United Imaging uCT510 / 512 / 530 / 550 · Neusoft Neuviz 16 / 16Essence / 16Platinum · Anke ANATOM 16 / 16HD · Minfound ScintCare CT16 / CT32 / mCT32 / 736 · Sino Vision Insitum 16 / 32 / 64S / CT368 / 398 / 568 · Quantum CT Q580 / 588 · Shinva XHCT-16 · Envision LCT16 |
|---|---|
| RIMION replacement | MH5006 |
Which RIMION tube fits Neusoft, United Imaging and other Chinese CT brands?
The RIMION MH3505 fits Neusoft Neuviz ACE/SP, Minfound ScintCare and Blue series, United Imaging uCT 528, Sino Vision Insitum, Anke ANATOM 32Fit, Quantum CT Q560 and Campo Precision 128. The MH4006 and MH5006 cover Neusoft Neuviz and United Imaging uCT 510/512/530/550.
What original tube does the MH3505 replace?
The MH3505 is an alternative to the GS307X series tube — compatible with multiple 16-row CT models from Neusoft, Minfound, United Imaging, Anke and other Chinese brands.
Master Replacement Table
Quick reference — scanner brand, compatible models and the corresponding RIMION replacement tube.
| Brand | Scanner Models | RIMION Tube |
|---|---|---|
| GE | HiSpeed · BrightSpeed Elite / Edge / Excel Select · Optima CT520 · Optima Advance · Revolution Advance · Revolution Eagle | MH3501 |
| GE | Optima 540 · CT660 · BrightSpeed Edge / Elite / Excel · Discovery PET/CT 600 / RX · HiSpeed CT · LightSpeed 16 | MH6301 |
| Siemens | Emotion · Scope · Go now / Go up (replaces DURA202, DURA352, CHRONON) | MH3502 |
| Siemens | Somatom Emotion 6 / 16 · Scope · Scope Power · Perspective 64 / 128 · Emotion PET | MH6002 |
| Siemens | Somatom Perspective 64 | MH6002A |
| Philips | Access Dual · MX4000 · Access16 · MX6000 | MH4006 |
| Philips | MX16 · 16EVO (replaces DU5008 / CTR2150) | MH5006 |
| Philips | Brilliance CT 6 / 10 / 16 · Ingenuity Flex 16 | MH6003L |
| Canon | Alexion 16 / Access · Asteion VF / 4 / S4 | MH3504A |
| Chinese | Neusoft Neuviz ACE / SP · Minfound ScintCare & Blue · United Imaging uCT 528 · Sino Vision Insitum · Anke ANATOM 32Fit · Quantum CT Q560 · Campo Precision 128 | MH3505 |
| Chinese | Neusoft Neuviz Twin / Dual / 16 Classic | MH4006 |
| Chinese | United Imaging uCT 510 / 512 / 530 / 550 · Neusoft Neuviz 16 · Anke ANATOM 16 · Minfound ScintCare · Sino Vision Insitum · Quantum CT Q580 · Shinva · Envision | MH5006 |
Replacement Questions
Common questions when selecting a RIMION replacement tube for a CT scanner.
Which RIMION tube replaces the GE MX165?
The RIMION MH3501 is a 1:1 drop-in replacement for the GE MX165 tube, compatible with GE HiSpeed, BrightSpeed Elite/Edge/Excel Select, Optima CT520, Optima Advance, Revolution Advance and Revolution Eagle CT scanners.
Which RIMION tube replaces the Siemens DURA202, DURA352 and CHRONON?
The RIMION MH3502 is a direct alternative for the Siemens DURA202, DURA352 and CHRONON tubes, compatible with Siemens Emotion, Scope and Go now/up CT systems.
Which RIMION tube replaces the Philips CTR2150?
The RIMION MH5006 is an alternative to the Philips DU5008 and CTR2150 tubes, compatible with Philips MX16 / 16EVO and multiple 16-row CT models from other brands.
Which RIMION tube is compatible with Canon Alexion and Asteion?
The RIMION MH3504A is compatible with Canon Alexion 16, Alexion Access, Asteion VF, Asteion 4 and Asteion S4 CT scanners.
Which RIMION tube fits Neusoft, United Imaging and other Chinese CT brands?
The RIMION MH3505 fits Neusoft Neuviz ACE/SP, Minfound ScintCare and Blue, United Imaging uCT 528, Sino Vision Insitum, Anke ANATOM 32Fit, Quantum CT Q560 and Campo Precision 128. The MH4006 and MH5006 cover Neusoft Neuviz and United Imaging uCT 510/512/530/550.
How do I confirm the right tube for my scanner?
Contact RIMION with your scanner brand, model number and current tube model. Our export team will match the correct RIMION replacement and reply within 24 hours.
Are RIMION replacement tubes drop-in compatible?
Yes. RIMION CT replacement tubes are engineered as 1:1 drop-in replacements — no mechanical modification, no firmware changes and no scanner reconfiguration required in most cases.
What warranty does RIMION provide on replacement tubes?
Every RIMION CT replacement tube comes with a 12-month warranty covering manufacturing defects, plus full-lifecycle after-sales support and 24/7 technical assistance.
Explore More
Related pages for product specifications, after-sales support and global supply.
Not Sure Which Tube Fits Your Scanner?
Send us your scanner brand, model number and current tube code — our team will match the right RIMION replacement within 24 hours.